Fermé lundi 19 mai / Closed May 19th
Livraison gratuite sur commandes en ligne de $200 et plus.
Free shipping for online orders over $200.
{"id":8901700550892,"title":"BioMed Flex 80A Resin 1L (Form 3B)","handle":"biomed-flex-80a-resin-1l-form3b","description":"\u003cdiv align=\"justify\"\u003e\n\u003cp\u003eBioMed Flex 80A Resin is a firm, flexible, and transparent material for biocompatible applications requiring durability and long-term skin (\u0026gt;30 days) or short-term mucosal membrane contact (\u0026lt;24 hours).\u003c\/p\u003e\n\u003cp\u003eBioMed Flex 80A Resin is manufactured in our FDA-registered, ISO 13485 certified facility.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003ePost-curing is required. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Header_headerText__erapV Header_as-h4__Y2Ob8 Header_weight-700__NTHpg Header_light__j0TFO Header_light-primary__XUSia\"\u003eWhy Choose BioMed Flex 80A Resin?\u003c\/h2\u003e\n\u003cdiv class=\"TextPlugin_light__vLNDo TextPlugin_text-plugin__3BZXB TextPlugin_theme__WsfWn\"\u003e\n\u003cp\u003eAchieve new design possibilities and efficiencies using 3D printing and BioMed Flex 80A Resin, from producing flexible biocompatible medical devices to anatomical models requiring biocompatibility.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_grid-x__M23th Grid_grid-padding-x__xTuFF Grid_stretch__XuYGx\"\u003e\n\u003cdiv class=\"Grid_cell__jxxjs light Grid_small-24__YV7NB Grid_medium-24__47Wwp Grid_large-12__saMdZ Grid_small-offset-0__0Tjx6 Grid_medium-offset-0__vs8uW Grid_large-offset-0__QEG6e\"\u003e\n\u003cdiv\u003e\n\u003ci class=\"fl-v2 fl-v2-fl-strong_precise Icon_black__3Fzk3 Icon_icon___a8Fw SimpleCallout_icon__hPpFF\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\n\u003ch3 class=\"SimpleCallout_title__gQ5vS\"\u003eFlexible\u003c\/h3\u003e\n\u003cp class=\"SimpleCallout_callout-text__MsST2\"\u003eProduce flexible medical devices or firm tissue models requiring short-term mucosal membrane contact that can optimize mass personalization applications versus using cumbersome molds.\u003ci class=\"fl-v2 fl-v2-fl-stethoscope Icon_black__3Fzk3 Icon_icon___a8Fw SimpleCallout_icon__hPpFF\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_cell__jxxjs light Grid_small-24__YV7NB Grid_medium-24__47Wwp Grid_large-12__saMdZ Grid_small-offset-0__0Tjx6 Grid_medium-offset-0__vs8uW Grid_large-offset-0__QEG6e\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"SimpleCallout_title__gQ5vS\"\u003eTransparent\u003c\/h3\u003e\n\u003cp class=\"SimpleCallout_callout-text__MsST2\"\u003eProduce complex transparent firm tissue models and bring them directly into the operating room (O.R.) as a reference for complex medical procedures (eg. sizing models, cartilage models, or disease organs.)\u003ci class=\"fl-v2 fl-v2-fl-hospital_board_square Icon_black__3Fzk3 Icon_icon___a8Fw SimpleCallout_icon__hPpFF\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_grid-x__M23th Grid_grid-padding-x__xTuFF Grid_stretch__XuYGx\"\u003e\n\u003cdiv class=\"Grid_cell__jxxjs light Grid_small-24__YV7NB Grid_medium-24__47Wwp Grid_large-12__saMdZ Grid_small-offset-0__0Tjx6 Grid_medium-offset-0__vs8uW Grid_large-offset-0__QEG6e\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"SimpleCallout_title__gQ5vS\"\u003eMedical-Grade Material, Biocompatible Parts\u003c\/h3\u003e\n\u003cp class=\"SimpleCallout_callout-text__MsST2\"\u003eLeverage a material manufactured within our Quality Management Systems, with strict adherence to ISO 13485. Instill confidence that this material is suitable for biocompatible applications with long-term skin (\u0026gt;30 days), short-term mucosal membrane contact (\u0026lt;24 hours), and USP Class VI certifications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"Header_headerText__erapV Header_as-h4__Y2Ob8 Header_weight-700__NTHpg Header_light__j0TFO Header_theme__gG0vm\"\u003eApplications*\u003c\/h2\u003e\n\u003cdiv class=\"TextPlugin_text-plugin__3BZXB TextPlugin_theme__WsfWn\"\u003e\n\u003cp\u003eDirectly 3D print flexible parts requiring biocompatibility with BioMed Flex 80A Resin. Reduce workflow times by eliminating molding to directly produce flexible, patient-specific medical devices or firm tissue medical models surgeons can reference in the O.R.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eBioMed Flex 80A Resin is ideal for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_grid-x__M23th Grid_stretch__XuYGx\"\u003e\n\u003cdiv class=\"Grid_cell__jxxjs Grid_small-24__YV7NB Grid_medium-12__Lt5EN Grid_large-12__saMdZ Grid_small-offset-0__0Tjx6 Grid_medium-offset-0__vs8uW Grid_large-offset-0__QEG6e\"\u003e\n\u003cdiv class=\"CheckmarkList_list-container__YgcKN\"\u003e\n\u003cdiv class=\"CheckmarkList_columns-1__2uQWd CheckmarkList_margin-vertical-2__hZQyt CheckmarkList_item__hi0M8 CheckmarkList_font-size-0__tjnxT\"\u003e\n\u003ci class=\"fl-v2 fl-v2-fl-circle_check_solid Icon_blue__NrUnM Icon_icon___a8Fw\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\u003cspan class=\"CheckmarkList_single-line__oAEjo\"\u003eFlexible biocompatible medical devices and components\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"CheckmarkList_columns-1__2uQWd CheckmarkList_margin-vertical-2__hZQyt CheckmarkList_item__hi0M8 CheckmarkList_font-size-0__tjnxT\"\u003e\n\u003ci class=\"fl-v2 fl-v2-fl-circle_check_solid Icon_blue__NrUnM Icon_icon___a8Fw\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\u003cspan class=\"CheckmarkList_single-line__oAEjo\"\u003eMedical devices requiring short-term mucosal membrane contact\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_cell__jxxjs Grid_small-24__YV7NB Grid_medium-12__Lt5EN Grid_large-12__saMdZ Grid_small-offset-0__0Tjx6 Grid_medium-offset-0__vs8uW Grid_large-offset-0__QEG6e\"\u003e\n\u003cdiv class=\"CheckmarkList_list-container__YgcKN\"\u003e\n\u003cdiv class=\"CheckmarkList_columns-1__2uQWd CheckmarkList_margin-vertical-2__hZQyt CheckmarkList_item__hi0M8 CheckmarkList_font-size-0__tjnxT\"\u003e\n\u003ci class=\"fl-v2 fl-v2-fl-circle_check_solid Icon_blue__NrUnM Icon_icon___a8Fw\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\u003cspan class=\"CheckmarkList_single-line__oAEjo\"\u003eFirm tissue models to assist in surgeries\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003e\u003cspan\u003e*Unlike Formlabs Dental Resins, no intended uses are provided for BioMed Resins. Material properties may vary based on part design, manufacturing practices, and other methods. It is the manufacturer’s responsibility and its respective customers and end-users to determine the biocompatibility and performance of all printed parts for their respective application and use. To instill confidence in potential users, Formlabs has tested biocompatibility for common use cases and manufactures BioMed Resins in an ISO 13485-certified facility. We can offer representative examples of what customers have done with our products and the supporting documentation we make freely available.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003e\n\u003cdiv class=\"Grid_section__NbaNC light\" id=\"material-headline\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"Grid_section__hLX0Q light\"\u003e\n\u003cdiv class=\"Grid_grid-x__rSPX7 Grid_grid-margin-x__MQ6jY Grid_stretch__DdkNX\"\u003e\n\u003cdiv class=\"Grid_cell__eQjhu light Grid_small-24__Mhk86 Grid_medium-8__l_c_L Grid_large-8__3LN_a Grid_small-offset-0__RgpwR Grid_medium-offset-8__6cv87 Grid_large-offset-8__As2G7\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"CombinedHeadlines_removeMarginChildren__POo4I\"\u003e\n\u003ch2 class=\"Header_headerText__erapV Header_as-h4__Y2Ob8 Header_weight-700__NTHpg Header_light__j0TFO Header_light-primary__XUSia\"\u003eMaterial Properties*\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_section__hLX0Q Grid_grid-container__oSf0V\" id=\"material-properties\"\u003e\n\u003cdiv class=\"ComparisonTable_comparison-table__Oz3pO ComparisonTable_columns-1__3mh79\"\u003e\n\u003cdiv class=\"ComparisonTable_table-column__e5YQa ComparisonTable_col-1__1GCYC ComparisonTable_light__rcwd2\"\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_row-1__dscBS ComparisonTable_drop-down__dJqor\"\u003e\n\u003cp class=\"ComparisonTable_column-title__4cbif\"\u003eBioMed Flex 80A Resin\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_first__TXWNG ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eUltimate Tensile Strength: 7.2 MPa\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eStress at 50% Elongation: 2.6 MPa\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eStress at 100% Elongation: 4.5 MPa\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eElongation: 135%\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eTear Strength: 22 kN\/m\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eHardness Shore A: 80A\u003c\/p\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2025-05-15T10:08:22-04:00","created_at":"2025-05-15T09:19:50-04:00","vendor":"Formlabs","type":"Résines Formlabs","tags":["Biomed","Flex","Form 3B","formlabs","resin"],"price":35607,"price_min":35607,"price_max":35607,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":46443548639468,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FLB-MED-FLX-80A-01L","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"BioMed Flex 80A Resin 1L (Form 3B)","public_title":null,"options":["Default Title"],"price":35607,"weight":1650,"compare_at_price":null,"inventory_quantity":1,"inventory_management":"shopify","inventory_policy":"deny","barcode":"811294034844","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/www.voxelfactory.com\/cdn\/shop\/files\/Formlabs_Biomed_Flex_80A_1L_Form3_Product_Picture.webp?v=1747316684"],"featured_image":"\/\/www.voxelfactory.com\/cdn\/shop\/files\/Formlabs_Biomed_Flex_80A_1L_Form3_Product_Picture.webp?v=1747316684","options":["Title"],"media":[{"alt":"Formlabs Biomed Flex 80A 1L Form3 Product Picture","id":35362859352300,"position":1,"preview_image":{"aspect_ratio":1.333,"height":1050,"width":1400,"src":"\/\/www.voxelfactory.com\/cdn\/shop\/files\/Formlabs_Biomed_Flex_80A_1L_Form3_Product_Picture.webp?v=1747316684"},"aspect_ratio":1.333,"height":1050,"media_type":"image","src":"\/\/www.voxelfactory.com\/cdn\/shop\/files\/Formlabs_Biomed_Flex_80A_1L_Form3_Product_Picture.webp?v=1747316684","width":1400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv align=\"justify\"\u003e\n\u003cp\u003eBioMed Flex 80A Resin is a firm, flexible, and transparent material for biocompatible applications requiring durability and long-term skin (\u0026gt;30 days) or short-term mucosal membrane contact (\u0026lt;24 hours).\u003c\/p\u003e\n\u003cp\u003eBioMed Flex 80A Resin is manufactured in our FDA-registered, ISO 13485 certified facility.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003ePost-curing is required. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"Header_headerText__erapV Header_as-h4__Y2Ob8 Header_weight-700__NTHpg Header_light__j0TFO Header_light-primary__XUSia\"\u003eWhy Choose BioMed Flex 80A Resin?\u003c\/h2\u003e\n\u003cdiv class=\"TextPlugin_light__vLNDo TextPlugin_text-plugin__3BZXB TextPlugin_theme__WsfWn\"\u003e\n\u003cp\u003eAchieve new design possibilities and efficiencies using 3D printing and BioMed Flex 80A Resin, from producing flexible biocompatible medical devices to anatomical models requiring biocompatibility.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_grid-x__M23th Grid_grid-padding-x__xTuFF Grid_stretch__XuYGx\"\u003e\n\u003cdiv class=\"Grid_cell__jxxjs light Grid_small-24__YV7NB Grid_medium-24__47Wwp Grid_large-12__saMdZ Grid_small-offset-0__0Tjx6 Grid_medium-offset-0__vs8uW Grid_large-offset-0__QEG6e\"\u003e\n\u003cdiv\u003e\n\u003ci class=\"fl-v2 fl-v2-fl-strong_precise Icon_black__3Fzk3 Icon_icon___a8Fw SimpleCallout_icon__hPpFF\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\n\u003ch3 class=\"SimpleCallout_title__gQ5vS\"\u003eFlexible\u003c\/h3\u003e\n\u003cp class=\"SimpleCallout_callout-text__MsST2\"\u003eProduce flexible medical devices or firm tissue models requiring short-term mucosal membrane contact that can optimize mass personalization applications versus using cumbersome molds.\u003ci class=\"fl-v2 fl-v2-fl-stethoscope Icon_black__3Fzk3 Icon_icon___a8Fw SimpleCallout_icon__hPpFF\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_cell__jxxjs light Grid_small-24__YV7NB Grid_medium-24__47Wwp Grid_large-12__saMdZ Grid_small-offset-0__0Tjx6 Grid_medium-offset-0__vs8uW Grid_large-offset-0__QEG6e\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"SimpleCallout_title__gQ5vS\"\u003eTransparent\u003c\/h3\u003e\n\u003cp class=\"SimpleCallout_callout-text__MsST2\"\u003eProduce complex transparent firm tissue models and bring them directly into the operating room (O.R.) as a reference for complex medical procedures (eg. sizing models, cartilage models, or disease organs.)\u003ci class=\"fl-v2 fl-v2-fl-hospital_board_square Icon_black__3Fzk3 Icon_icon___a8Fw SimpleCallout_icon__hPpFF\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_grid-x__M23th Grid_grid-padding-x__xTuFF Grid_stretch__XuYGx\"\u003e\n\u003cdiv class=\"Grid_cell__jxxjs light Grid_small-24__YV7NB Grid_medium-24__47Wwp Grid_large-12__saMdZ Grid_small-offset-0__0Tjx6 Grid_medium-offset-0__vs8uW Grid_large-offset-0__QEG6e\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"SimpleCallout_title__gQ5vS\"\u003eMedical-Grade Material, Biocompatible Parts\u003c\/h3\u003e\n\u003cp class=\"SimpleCallout_callout-text__MsST2\"\u003eLeverage a material manufactured within our Quality Management Systems, with strict adherence to ISO 13485. Instill confidence that this material is suitable for biocompatible applications with long-term skin (\u0026gt;30 days), short-term mucosal membrane contact (\u0026lt;24 hours), and USP Class VI certifications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 class=\"Header_headerText__erapV Header_as-h4__Y2Ob8 Header_weight-700__NTHpg Header_light__j0TFO Header_theme__gG0vm\"\u003eApplications*\u003c\/h2\u003e\n\u003cdiv class=\"TextPlugin_text-plugin__3BZXB TextPlugin_theme__WsfWn\"\u003e\n\u003cp\u003eDirectly 3D print flexible parts requiring biocompatibility with BioMed Flex 80A Resin. Reduce workflow times by eliminating molding to directly produce flexible, patient-specific medical devices or firm tissue medical models surgeons can reference in the O.R.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cstrong\u003eBioMed Flex 80A Resin is ideal for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_grid-x__M23th Grid_stretch__XuYGx\"\u003e\n\u003cdiv class=\"Grid_cell__jxxjs Grid_small-24__YV7NB Grid_medium-12__Lt5EN Grid_large-12__saMdZ Grid_small-offset-0__0Tjx6 Grid_medium-offset-0__vs8uW Grid_large-offset-0__QEG6e\"\u003e\n\u003cdiv class=\"CheckmarkList_list-container__YgcKN\"\u003e\n\u003cdiv class=\"CheckmarkList_columns-1__2uQWd CheckmarkList_margin-vertical-2__hZQyt CheckmarkList_item__hi0M8 CheckmarkList_font-size-0__tjnxT\"\u003e\n\u003ci class=\"fl-v2 fl-v2-fl-circle_check_solid Icon_blue__NrUnM Icon_icon___a8Fw\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\u003cspan class=\"CheckmarkList_single-line__oAEjo\"\u003eFlexible biocompatible medical devices and components\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"CheckmarkList_columns-1__2uQWd CheckmarkList_margin-vertical-2__hZQyt CheckmarkList_item__hi0M8 CheckmarkList_font-size-0__tjnxT\"\u003e\n\u003ci class=\"fl-v2 fl-v2-fl-circle_check_solid Icon_blue__NrUnM Icon_icon___a8Fw\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\u003cspan class=\"CheckmarkList_single-line__oAEjo\"\u003eMedical devices requiring short-term mucosal membrane contact\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_cell__jxxjs Grid_small-24__YV7NB Grid_medium-12__Lt5EN Grid_large-12__saMdZ Grid_small-offset-0__0Tjx6 Grid_medium-offset-0__vs8uW Grid_large-offset-0__QEG6e\"\u003e\n\u003cdiv class=\"CheckmarkList_list-container__YgcKN\"\u003e\n\u003cdiv class=\"CheckmarkList_columns-1__2uQWd CheckmarkList_margin-vertical-2__hZQyt CheckmarkList_item__hi0M8 CheckmarkList_font-size-0__tjnxT\"\u003e\n\u003ci class=\"fl-v2 fl-v2-fl-circle_check_solid Icon_blue__NrUnM Icon_icon___a8Fw\" aria-hidden=\"true\" role=\"presentation\"\u003e\u003c\/i\u003e\u003cspan class=\"CheckmarkList_single-line__oAEjo\"\u003eFirm tissue models to assist in surgeries\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003e\u003cspan\u003e*Unlike Formlabs Dental Resins, no intended uses are provided for BioMed Resins. Material properties may vary based on part design, manufacturing practices, and other methods. It is the manufacturer’s responsibility and its respective customers and end-users to determine the biocompatibility and performance of all printed parts for their respective application and use. To instill confidence in potential users, Formlabs has tested biocompatibility for common use cases and manufactures BioMed Resins in an ISO 13485-certified facility. We can offer representative examples of what customers have done with our products and the supporting documentation we make freely available.\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003e\n\u003cdiv class=\"Grid_section__NbaNC light\" id=\"material-headline\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"Grid_section__hLX0Q light\"\u003e\n\u003cdiv class=\"Grid_grid-x__rSPX7 Grid_grid-margin-x__MQ6jY Grid_stretch__DdkNX\"\u003e\n\u003cdiv class=\"Grid_cell__eQjhu light Grid_small-24__Mhk86 Grid_medium-8__l_c_L Grid_large-8__3LN_a Grid_small-offset-0__RgpwR Grid_medium-offset-8__6cv87 Grid_large-offset-8__As2G7\"\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"CombinedHeadlines_removeMarginChildren__POo4I\"\u003e\n\u003ch2 class=\"Header_headerText__erapV Header_as-h4__Y2Ob8 Header_weight-700__NTHpg Header_light__j0TFO Header_light-primary__XUSia\"\u003eMaterial Properties*\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"Grid_section__hLX0Q Grid_grid-container__oSf0V\" id=\"material-properties\"\u003e\n\u003cdiv class=\"ComparisonTable_comparison-table__Oz3pO ComparisonTable_columns-1__3mh79\"\u003e\n\u003cdiv class=\"ComparisonTable_table-column__e5YQa ComparisonTable_col-1__1GCYC ComparisonTable_light__rcwd2\"\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_row-1__dscBS ComparisonTable_drop-down__dJqor\"\u003e\n\u003cp class=\"ComparisonTable_column-title__4cbif\"\u003eBioMed Flex 80A Resin\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_first__TXWNG ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eUltimate Tensile Strength: 7.2 MPa\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eStress at 50% Elongation: 2.6 MPa\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eStress at 100% Elongation: 4.5 MPa\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eElongation: 135%\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cdiv\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eTear Strength: 22 kN\/m\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ComparisonTable_column-data__cPOUZ ComparisonTable_white__XWaAB ComparisonTable_center__aI5jg\"\u003e\n\u003cdiv class=\"ComparisonTable_grid-content__Xjf2z ComparisonTable_middle__N3Dhz\"\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003eHardness Shore A: 80A\u003c\/p\u003e\n\u003cp class=\"ComparisonTable_label__cnfrm\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

BioMed Flex 80A Resin 1L (Form 3B)

Description du produit
Sku: FLB-MED-FLX-80A-01L
Vendeur: Formlabs

EN STOCK : 1

$356.07
La quantité maximale disponible est atteinte.

BioMed Flex 80A Resin is a firm, flexible, and transparent material for biocompatible applications requiring durability and long-term skin (>30 days) or short-term mucosal membrane contact (<24 hours).

BioMed Flex 80A Resin is manufactured in our FDA-registered, ISO 13485 certified facility.

Post-curing is required. 

Why Choose BioMed Flex 80A Resin?

Achieve new design possibilities and efficiencies using 3D printing and BioMed Flex 80A Resin, from producing flexible biocompatible medical devices to anatomical models requiring biocompatibility.

Flexible

Produce flexible medical devices or firm tissue models requiring short-term mucosal membrane contact that can optimize mass personalization applications versus using cumbersome molds.

Transparent

Produce complex transparent firm tissue models and bring them directly into the operating room (O.R.) as a reference for complex medical procedures (eg. sizing models, cartilage models, or disease organs.)

Medical-Grade Material, Biocompatible Parts

Leverage a material manufactured within our Quality Management Systems, with strict adherence to ISO 13485. Instill confidence that this material is suitable for biocompatible applications with long-term skin (>30 days), short-term mucosal membrane contact (<24 hours), and USP Class VI certifications.

Applications*

Directly 3D print flexible parts requiring biocompatibility with BioMed Flex 80A Resin. Reduce workflow times by eliminating molding to directly produce flexible, patient-specific medical devices or firm tissue medical models surgeons can reference in the O.R.


BioMed Flex 80A Resin is ideal for:

Flexible biocompatible medical devices and components Medical devices requiring short-term mucosal membrane contact Firm tissue models to assist in surgeries

*Unlike Formlabs Dental Resins, no intended uses are provided for BioMed Resins. Material properties may vary based on part design, manufacturing practices, and other methods. It is the manufacturer’s responsibility and its respective customers and end-users to determine the biocompatibility and performance of all printed parts for their respective application and use. To instill confidence in potential users, Formlabs has tested biocompatibility for common use cases and manufactures BioMed Resins in an ISO 13485-certified facility. We can offer representative examples of what customers have done with our products and the supporting documentation we make freely available.

Material Properties*

BioMed Flex 80A Resin

Ultimate Tensile Strength: 7.2 MPa

Stress at 50% Elongation: 2.6 MPa

Stress at 100% Elongation: 4.5 MPa

Elongation: 135%

Tear Strength: 22 kN/m

Hardness Shore A: 80A

 

Produits Connexes